Technical note

FARO Laser Tracker Price, CMM Arms, and Shop Measurement: 7 Questions I Wish I'd Asked First

I handle capital equipment and MRO purchasing for a mid-size fabrication shop — going on 9 years now. Over that stretch I've signed off on roughly $340,000 worth of metrology and test gear, and I've documented about $28,000 of it as avoidable mistakes. Maybe a little less; I'd have to pull the spreadsheet to be sure, but that order of magnitude.

What follows are the questions I now ask before any measurement-related purchase, roughly in the order they've cost me money. If you're evaluating a FARO laser tracker, a portable CMM arm, or something as small as a replacement caliper jaw, at least one of these should save you a phone call.

1. If I'm pricing a FARO laser tracker, what am I actually buying?

The number your rep quotes is for the head unit. What you pay is closer to that number plus 20–35%, and where the gap opens up depends on your application.

What I mean is: reflector targets aren't always bundled. Neither are the software licenses you'll need if you want to do anything beyond point-and-shoot — CAM2 ME, or a PolyWorks seat if your clients expect that workflow. Add first-year calibration and on-site training and the delta gets uncomfortable.

Two things I'd ask for explicitly:

  • A total-system quote — head, targets, software, cables, shipping, first calibration, training — in one document. If a vendor won't build that, that's informative in itself.
  • A written 3-year and 5-year calibration quote. Post-warranty calibration usually costs more than customers expect, and it's where the after-sales margin lives.

The most frustrating part: I only believed the total-quote advice after skipping it once on a smaller system and eating an $8,900 gap between the quoted price and the final invoice. Everyone told me to get the total number. I didn't listen.

2. FARO CMM arm or laser tracker — do I need both?

It depends on your working volume. That's genuinely the deciding factor, not the spec-sheet number your budget committee glues onto.

A laser tracker earns its money on large assemblies — weld fixtures, big machined parts, anything where you walk around the workpiece instead of the other way around. A FARO CMM arm is better for mid-size parts, hidden features, and the deep pockets and bores a tracker can't reach without a stack of extension tooling.

Honestly: if 90% of what you measure fits inside 1.5 meters and the measurement usually means reaching into the part, a laser tracker is probably an expensive mistake. I watched that happen once. The tracker was beautiful. It sat idle for two years and then got sold at a loss.

The reverse is just as common. If your work is mostly one-off big parts with fixture-sensitive tolerances, the arm is what collects dust. Plenty of shops end up with both, and the order usually gets decided by which job type piles up first.

3. Caliper parts — which ones are worth replacing, and which aren't?

Split the question, because "caliper parts" covers too much ground.

On a decent caliper, the slider assembly, lock screw, battery cover, and depth-rod end are all cheap to replace and keep the tool in service for years. Jaws are a different calculation. If jaw wear is creeping past 0.02 mm across the range, regrinding is usually cheaper than replacement — provided the caliper is worth $300 or more to begin with.

That said, on a 150 mm digital caliper under roughly $200, regrinding plus the downtime usually costs about a third of a new unit, and the new unit comes with fresh battery contacts and a clean slide. I've tried both. Only the expensive one was worth saving.

4. When does a cheap digital pressure gauge bite you?

Two places: the accuracy spec, and the temperature compensation behind it.

First, check what the percentage is a percentage of. ±0.25% of full scale and ±0.25% of reading are not the same thing. On a 100 psi gauge reading 10 psi, a full-scale spec is ±0.25 psi — roughly ±2.5% of the reading you actually care about. If you oversize the range, the datasheet number becomes worthless exactly where you're using it.

Second, anything living in a shop or a compressor room that hits 100°F in July will drift out of its stated accuracy. Cheap units are often calibrated well and then wander within the first warm week. If absolute pressure matters, spend the extra $40–60 on temperature-compensated. If trend matters more than a single reading — you're logging, not verifying — put the money into data logging instead. At least, that's been my experience on the process-side orders I handle.

5. Where should I buy a Fluke multimeter so I don't get sold a fake?

Authorized distributors. That's the whole answer, but it's more annoying to execute than it sounds.

Counterfeit and grey-market meters are real, and they're hard to spot from the outside — the housing, the sticker, the packaging all look right. The difference shows up inside. The manufacturer's authorized dealer list is the place to start; if a seller isn't on it, don't buy. If a price sits more than 30% under the authorized channel, it's either not genuine or not warrantied.

We ordered one from a perfectly respectable-looking web store that turned out to be drop-shipping. Serial number lookup came back empty. The return was a headache and the credit took three weeks. Compared to the $15–20 premium at an authorized seller, not worth the risk. If your test gear feeds into a controlled calibration system, a meter with no traceable provenance is a liability rather than a bargain.

6. Is a calibration certificate actually worth the money?

Depends entirely on who issued it, under what accreditation, and what it actually says.

A certificate from an ISO/IEC 17025 accredited laboratory, carrying the accreditation body's mark and a stated measurement uncertainty, is the kind an auditor or a picky customer will accept. A certificate that just says "calibrated" and gives a date — no uncertainty statement, no traceability chain — has more decorative value than practical value. If it came from the supplier's own lab with no third-party accreditation, be careful about relying on it.

Ask what's on the certificate before you buy: uncertainty statement, standards used, environmental conditions. If your client requires traceability to a national metrology institute, ask how the calibrator handles that specifically.

One more thing that cost me money: don't lock the calibration interval in place and forget it when circumstances change. We had a unit that started drifting not because the instrument was bad, but because it was being moved between sites far more often than the original interval assumed. The certificate was fine. The schedule wasn't.

7. When is portable metrology the wrong choice?

More often than most sales conversations will admit.

If you're measuring a production line at volume, 24/7, and repeatability matters more than portability, a fixed CMM in a temperature-controlled room is still the right tool. It isn't glamorous and it isn't flexible, but it's stable. Portable systems trade some stability for flexibility, and at high throughput they lose that trade.

The second case is subtler: shop-floor environment. Portable equipment is specified under controlled conditions. Put a tracker next to a stamping press, with no thermal stability and nothing anchoring the reference geometry, and you'll get accuracy well short of the spec — and the operator standing next to it will get blamed for the gap. That's not a tracker problem. That's an environment problem that needs its own budget line.

In my opinion, a portable system is the correct answer for about 80% of general measurement work. But if you're in the other 20%, buying on the wrong side of that line usually means buying the right tool later anyway, with a used unit and a burned budget to show for it. I learned that one the hard way, which is the whole reason I keep the checklist.

Luc Moreau

Luc Moreau

Luc Moreau is a large-scale dimensional systems analyst covering coordinate measuring machines, laser trackers, laser interferometers, video measuring machines, and profile projectors. He works from ISO 10360-2 and ISO 10360-10 concepts to compare probing error, length-measurement error, volumetric performance, environmental compensation, and maximum permissible error. He helps metrology laboratories and manufacturing engineers plan acceptance tests, estimate usable uncertainty, and match system capability to part size and tolerance.

Previous: Balluff Distance Sensors, Encoders, and Efector Laser Gear: A $4,300 Buyer's Guide By Scenario Next: Why 'Within Spec' Doesn't Mean It Works: Rethinking Instrument Verification