Technical note

Rush Orders Without the Runaround: A Scenario-Based Guide to Flow Meters, Lab Gear, and Thermal Imaging

There's no single 'right' way to handle an emergency equipment order

I'm a rush-order coordinator at an industrial automation distributor. I've handled 300+ emergency instrumentation orders over the last 8 years, including same-day turnarounds for chemical plants and food processing clients. When someone calls me in a panic, the first thing I do is figure out which scenario we're in. The advice I'd give for installing a Coriolis flow meter is completely different from what I'd say about getting a confocal microscope running by Monday.

Here's how I break it down:

  • Scenario A: Industrial process instrumentation—specifically an Endress+Hauser Coriolis flow meter installation that can't wait.
  • Scenario B: Lab equipment emergency—a confocal microscope or an Eppendorf pipette that needs to be in service fast.
  • Scenario C: Thermal imaging for troubleshooting—using a T865 thermal camera to find a problem before it becomes a shutdown.

I'll give you my playbook for each, then a quick way to figure out which one you're in.

Scenario A: The Coriolis flow meter Endress+Hauser installation that has to happen now

In March 2024, a small specialty chemical company called at 2 p.m. on a Thursday. They needed an Endress+Hauser Coriolis flow meter installed and calibrated by Saturday morning. Normal turnaround for that scope? Five to seven business days. We had 36 hours.

Here's what I've learned from similar rush jobs: the installation guide matters more than the spec sheet. If you're following the Endress+Hauser flow meter installation guide for a Coriolis flow meter, Endress+Hauser's official documentation (endress.com) is thorough—but when you're in a hurry, you can skip steps that seem minor and pay for it later.

Three things that actually cause problems in a rush installation

1. Straight pipe runs. Coriolis meters need sufficient straight pipe upstream and downstream to avoid measurement errors. In a rush, people try to cut corners by mounting the meter close to an elbow. Don't. I've seen a 2% error turn into a 10% error because someone 'didn't have space.'

2. Zero calibration. You must zero the meter after installation with the pipe full and flow stopped. It takes maybe 15 minutes. Skipping it because you're behind schedule is false economy.

3. Grounding. This is where communication failures happen. I said 'standard grounding' once. The contractor heard 'whatever the electrician does.' Result: erratic readings for two days until we traced it to a missing ground strap.

What worked for us in that March 2024 job: we pre-staged the meter, flanges, and gaskets at the customer's site before the technician arrived. Paid an extra $800 in overtime, but saved the $12,000 project. (Should mention: we also had a backup plan to use a temporary ultrasonic clamp-on meter if the Coriolis install failed—didn't need it, but it kept everyone calm.)

One caveat: this worked for us because the fluid was a non-abrasive chemical at moderate temperature. If you're dealing with slurries or extreme temperatures, the calculus might be different.

Scenario B: Lab gear emergencies—confocal microscope or Eppendorf pipette

From the outside, it looks like lab equipment is easier to rush than industrial instruments. The reality is different: a confocal microscope needs careful alignment and calibration, and an Eppendorf pipette—even though it's a small item—has a learning curve that people underestimate.

I remember a university lab that ordered a single Eppendorf pipette on a Friday afternoon. They needed it Monday for a grant deadline. The order was under $300. We treated it like any other rush job—called the customer, confirmed the model, and sent a 15-minute video call link for a quick usage walkthrough. People assume small orders don't warrant that level of service. I disagree. When I was starting out, the vendors who took my $200 orders seriously are the ones I still use for $20,000 orders.

How to use Eppendorf pipette correctly when you're in a hurry

First, don't just watch a video and go. A quick search for 'how to use Eppendorf pipette' will give you plenty of tutorials, but the 'always aspirate slowly' advice ignores the nuance of different liquids. For aqueous solutions, a steady push is fine. For viscous or volatile liquids, you need a different technique. If I remember correctly, Eppendorf's manual recommends pre-wetting the tip three times for accurate results—though I might be misremembering the exact number. Check the manual.

For a confocal microscope, the rush priority is different. Don't try to do a full alignment if you're short on time. Focus on getting a usable image for your immediate experiment. Save the perfect alignment for when you have a day to spare.

Oh, and one more thing: if you're ordering lab equipment on a rush basis, confirm that the vendor includes calibration certificates. We've seen clients assume they're standard, then discover they're an add-on—which adds days to the turnaround.

Scenario C: Thermal camera troubleshooting with a T865

It's tempting to think a thermal camera is just 'point and shoot.' But a T865 thermal camera—or any high-end model—can give you misleading readings if you ignore emissivity and reflected temperature. I've seen maintenance teams chase a 'hot spot' that was actually a reflection off a shiny metal surface.

The T865 is a capable tool. According to FLIR's user manual (flir.com), you should set the material's emissivity and the reflected temperature before you start scanning. In a rush, people skip that and end up with false alarms.

Here's what I tell clients: if you're using a thermal camera for emergency troubleshooting, start with a known reference. Scan a surface you know is at ambient temperature. If the reading is off, your settings are wrong. Fix them before you start hunting for the real problem.

We don't sell FLIR cameras—we're an Endress+Hauser distributor—but I've coordinated enough rush orders where a thermal camera was part of the solution. The point is: the instrument is only as good as your setup. A $15,000 camera with wrong emissivity settings is worse than a $500 camera with correct settings.

How to figure out which scenario you're in

Ask yourself three questions:

  1. Is the equipment part of a safety-critical or production process? If yes, treat it like Scenario A. Don't rush the installation fundamentals—straight runs, grounding, calibration. The schedule pressure is real, but a failed installation costs more than a delayed one.
  2. Is this for a one-time experiment or a deadline-driven lab result? If yes, Scenario B. Prioritize getting a usable result over perfection. But don't skip calibration certificates on pipettes—they matter for reproducibility.
  3. Are you using the equipment to diagnose a problem, not to produce something? Then Scenario C. Take five minutes to set it up correctly. That five minutes saves an hour of false leads.

And regardless of scenario: if you're a small customer with a small order, don't accept being treated like an afterthought. A good supplier—whether for Endress+Hauser flow meters, lab pipettes, or thermal cameras—will give you the same attention on a $200 order as on a $20,000 one. That's not charity. It's good business.

Noura El-Sayed

Noura El-Sayed

Noura El-Sayed is an analytical and laboratory instrumentation analyst specializing in HPLC systems and columns, spectrophotometers, pH meters, pipettes, centrifuges, viscometers, and sample filters. She applies ISO 8655 liquid-handling methods and USP <621> chromatography principles while evaluating delivered volume, precision, flow accuracy, resolution, carryover, and detection limits. Her work helps laboratory managers and method developers select instruments, qualify workflows, and control sources of variability from sample preparation through analysis.

Previous: What a Sensus Water Meter Reading Taught Me About Paying for Certainty Next: FLIR One Gen 3 vs. Traditional Thermal Cameras: A Procurement Perspective